-40%

12-24V Adjustment 4-Channel 4-20Ma Current Signal Generator Source LCD Display

$ 10.02

Availability: 1003 in stock
  • Condition: New
  • Restocking Fee: No
  • EAN: Does not apply
  • UPC: Does not apply
  • Refund will be given as: Money Back
  • Brand: Unbranded/Generic
  • Return shipping will be paid by: Seller
  • MPN: Does not apply
  • Item must be returned within: 60 Days
  • All returns accepted: Returns Accepted

    Description

    Visit store
    Items for sale
    About us
    Product Details
    Features:
    The module is a multi-channel current signal generator, can produce 4 0 ~ 20mA current signal. Easy to use, enter the data by pressing the key to update the output signal immediately.
    With 12864 display
    Active current 0 ~ 20mA output, display resolution 0.01mA, control accuracy 0.1mA
    Input voltage anti-polarity protection
    The output of the transmitter can be simulated
    Product application:
    Signal generator
    Valve regulator
    Instrument calibration
    The interface description and related operations
    Interface (power interface)
    CN1 "+" indicates the positive terminal of the input power supply
    CN1 "-" indicates the negative (GND) of the input power supply
    CN1 "OUT1" indicates channel 1 to send current output
    CN1 "OUT2" indicates channel 2 to send current output
    CN1 "OUT3" indicates channel 3 to send current output
    CN1 "OUT4" indicates that channel 4 sends current output
    CN1 "G" indicates the common terminal GND
    Key description:
    Function keys K1: Up arrow keys are used to select the setting channel
    Function buttons K5: The lower arrow keys are used to select the setting channel
    Function button K2: Slowly minus 0.01 Press and hold 0.1
    Function button K3: Slow increase by 0.01 Press and hold 0.1
    Function key K6: actual value or percentage selection key
    Function button K8: clear key,
    The use of methods and steps:
    Output current OUT1 setting: Press the K1 key or K5 key to switch to the OUT1 setting interface, press the K2 or K3 output current value to 0.01MA step. Press and hold the K2 or K3 output current value in 0.1MA step
    Output current OUT2 setting: Press the K1 key or K5 key to switch to the OUT2 setting interface, press the K2 or K3 output current value to 0.01MA step. Press and hold the K2 or K3 output current value in 0.1MA step
    Output current OUT3 setting: Press the K1 key or K5 key to switch to the OUT3 setting interface, press the K2 or K3 output current value to 0.01MA steps. Press and hold the K2 or K3 output current value in 0.1MA step
    Output current OUT4 setting: Press the K1 key or K5 key to switch to the OUT4 setting interface, press the K2 or K3 output current value to 0.01MA steps. Press and hold the K2 or K3 output current value in 0.1MA step
    Package included:
    1*12-24V 6 Keys Adjustment 4-Channel 4-20Ma Signal Generator 12864 LCD Display
    Payment Method
    Shipping Policy
    Returns & Refund Policy
    Feedback
    Payment Method
    EBAY Managed Payment.
    But we only
    Accept
    your
    Ebay Address
    , please Make sure it's 100% right.
    Payment must be received in 5 business days of auction closing.
    Please leave note for your special request (e.g. Colors or Size) in PayPal when you pay the order.
    Any special request cannot be accepted after 24 hours of payment, because most of orders will be processed instantly and same day dispatched.
    Shipping Policy
    1. We only ship to the confirmed address provided by eBay. please make sure your ebay address is 100% matches the address you would like us to ship to. If not, please let us know before we sent you the package, or we will not be responsible for any loss. hope you could understand.
    2. Orders will be processed instantly and dispatched within 1-3 business days except hoilday, so we do NOT accept any email/message note after you place orders.
    3. All package need to wait 30 days,Please take care it.Less than 30 days,we can't take a refund.
    Returns & Refund Policy
    All package need to
    wait 30 days
    (US only n
    eed 7-10 days)
    ,
    Please take care it.Less than 30 days,we can't take a refund
    .
    If the item is defect when you receive it or you are not satisfied with it, please return it within 14 days for a replacement or money back. But the items must be back in factory condition. Please keep in touch with us and double check the return address before you return it.
    If is item is defective in 12 months, you can return it to us. We will send you a new replacement after receiving the defective item.
    Feedback
    We maintain high standards of excellence and strive for 100% customer satisfaction! Feedback is very important to us. We request that you keep in touch with us immediately BEFORE you give us neutral or negative feedback, so that we can satisfactorily address your concerns.
    On Jul-08-21 at 00:00:34 PDT, seller added the following information: